Skip to main content
Expertise · 02 / 04

Modernise without replacing. Extend the useful life of your plant.

Rather than scrapping a still-working machine, we reconfigure the refrigeration cycle, swap high-GWP refrigerants for low-carbon alternatives, and bring controls back to state of the art. Economical, ecological, quick to implement.

−60% GWP

typical reduction in global-warming potential after refrigerant swap

6-18 mo

average payback time for a full refurbishment

F-Gas

compliance with EU refrigerant regulation 2024-2030

Our approach

A modular approach: you choose the depth of works.

From a simple refrigerant swap to a full refurbishment of a production plant, each mission is scoped against your operational constraints and budget.

01

Targeted diagnostic

Detailed machine inspection, history review, precise identification of pain points.

02

Solution design

Refrigerant choice, sizing, updated refrigeration scheme, thermodynamic validation.

03

Execution

Works management: regulated recovery of old refrigerants, conversion, mechanical adjustments.

04

Commissioning & follow-up

Performance tests, control calibration, follow-up period with validation measurements.

Deliverables

What we hand over at the end of the mission.

Technical documents, measurable data, an immediately usable action plan.

Cooling regime optimisation

Floating condensation and evaporation setpoints, load-adaptive control, sub-cooling and heat recovery to maximise the COP.

AI-enhanced standardised controls

Controller upgrade with adaptive algorithms trained on the plant's operating patterns; seamless integration with the existing BMS.

Performance monitoring

Post-commissioning dashboard with automatic energy KPI logging and verification of actual savings over 6 to 12 months.

Regulatory dossier

Full DOE (as-built dossier), updated installation plan and operating procedures.

Use cases

When to refurbish rather than replace?

HCFC/HFC

Obsolete refrigerant fleet

Your R22, R404A, R134a are on borrowed time. Anticipate the F-Gas phase-out.

Ageing machines

Compressors losing COP

Degraded performance but sound frame: refurbishment is more cost-effective.

Legacy controls

Manual or obsolete control

Fast savings on consumption without touching the mechanics.

Industry

Food & beverage plants

Conversion to NH₃ or transcritical CO₂ for massive decarbonisation.

Commercial

Commercial chillers

Cycle optimisation on chilled-water plants.

Data centres

Technical rooms

Move to free-cooling, waste-heat valorisation.

Technologies & scope

Refrigerants and technologies mastered

Low-GWP fluidsR290 (propane), R600a, R1234yf, R1234ze, R513A, R454B
Natural fluidsAmmonia R717 (industrial), CO₂ R744 (transcritical / cascade)
CompressorsScroll, screw, piston (Inverter and tandem versions)
ControlsCarel, Danfoss, Schneider, Siemens; BACnet, Modbus, KNX
ComplianceF-Gas (EU 517/2014 then 573/2024), ISO 5149, EN 378
CertificationsCategory I refrigerant handling, ASME IX welders

Does your plant still have lives ahead of it?

Send us a datasheet or schematic: we assess the refurbishment potential within 5 days.